Abstract
PurposeThis paper provides a summary of the issues in the passive fire protection of steel structures. Types of passive fire protection and the material properties of protection members and steel members are described. The paper deals with the possibility of partial fire protection for secondary steel beams, in cases where, due to possible membrane action, it is not necessary to apply passive protection to the entire beams.Design/methodology/approachStudies of partially fire-protected steel structures are compared, and results from studies with different input data are summarized. A fire experiment was conducted to investigate the effect of partial passive protection in a small-scale furnace. Based on the findings of the experiment, numerical models were prepared using Ansys Mechanical.FindingsThe results are summarized, and a partial fire protection length of 500 mm is recommended. Various partial fire protection lengths were compared, and the temperature development of the steel contactors was compared using a protection length of 500 mm. At the end of the paper, options for partial passive protection of steel beams are presented.Originality/valueExtended paper from ASFE2021 based on selection.
Subject
Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献