Author:
Rajendran S.,Apparao B.V.,Palaniswamy N.
Abstract
The formulation consisting of 300ppm 1‐hydroxyethane‐1, 1‐diphosphonic acid (HEDP), 50ppm polyacrylamide (PAA) and 50 ppm Zn2+ offered 99 per cent corrosion inhibition and 99 to 99.9 per cent biocidal inhibition to mild steel in neutral aqueous environment containing 60ppm Cl‐ , a situation commonly encountered in cooling water systems. The nature of the protective film formed on the metal surface was analysed using X‐ray diffraction, UV‐visible reflectance, FTIR and luminescence spectra. The film was found to be luminescent and to consist of Fe2+ ‐HEDP complex, Fe2+ ‐PAA complex and Zn(OH)2.
Subject
General Materials Science,General Chemical Engineering
Reference14 articles.
1. Fang, J.L., Li, Y., Ye, X.R., Wang, Z.W. and Liu, Q. (1993), Corrosion, Vol. 49, p. 266.
2. Favre, M. and Landolt, D. (1993), Corrosive Science, Vol. 34, p. 1481.
3. Gunasekaran, G., Palaniswamy, N., Apparao, B.V. and Muralidharan, V.S. (1997), Electrochim. Acta, Vol. 49, p. 1427.
4. Hatch, G.B. and Ralston, P.H. (1972), Mat. Pro. Perf., Vol. 11, p. 39.
5. Horner, l. and Horner, C.L. (1976), Werkst. Korros., Vol. 27, p. 223.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献