Author:
K.H. Jyothiprakash,Y.T. Krishnegowda,Venkataram Krishna,Seetharamu K.N.
Abstract
Purpose
Heat exchangers working in cryogenic temperature ranges are strongly affected by heat ingression from the ambient. This paper aims to investigate the effect of ambient heat-in-leak on the performance of a three-fluid cross-flow cryogenic heat exchanger.
Design/methodology/approach
The governing equations are derived for a three-fluid cross-flow cryogenic heat exchanger based on the conservation of energy principle. For given fluid inlet temperatures, the governing equations are solved using the finite element method to obtain exit temperatures of the three-fluid exchanger. The performance of the heat exchanger is determined using effectiveness-number of transfer units (e-NTU) method. In the present analysis, the amount of ambient heat-in-leak to the heat exchanger is accounted by two parameters Ht and Hb. The variation of the heat exchanger effectiveness due to ambient heat-in-leak is analyzed for various non-dimensional parameters defined to study the heat exchanger performance.
Findings
The effect of ambient heat in leak to the heat exchanger from the surrounding is to increase the dimensionless exit mean temperature of all three fluids. An increase in heat in leak parameter (Ht = Hb) value from 0 to 0.1 reduces hot fluid effectiveness by 32 per cent for an NTU value of 10.
Originality Value
The effect of heat-in-leak on a three-fluid cross-flow cryogenic heat exchanger is significant, but so far, no investigations are carried out. The results establish the efficacy of the method and throw light on important considerations involved in the design of such heat exchangers.
Subject
Applied Mathematics,Computer Science Applications,Mechanical Engineering,Mechanics of Materials
Reference47 articles.
1. Parallel-flow heat exchangers with ambient thermal interaction;Heat Transfer Engineering,2000
2. Countercurrent heat exchangers with both fluids subjected to external heating;Heat Transfer Engineering,2010
3. Performances of three-fluid single pass cross flow heat exchanger;Heat Transfer,1982
4. Fast transient solution of a two‐layered counter‐flow microchannel heat sink;International Journal of Numerical Methods for Heat and Fluid Flow,2009
Cited by
8 articles.
订阅此论文施引文献