RAPTOR: The Innovation for Making Long Leg Standing Radiography for Total Knee Arthroplasty from Conventional Radiography

Author:

Srithongkul Pakorn,Koomchaya Atorn,Woratanarat Patarawan,Limsricharoen Warodom,Yusuwan Kittipong,Kowsomjeen Katcharin

Abstract

Purpose: To evaluate the reliability and validity of femoral anatomical-mechanical angle (fAMA), hip knee ankle angle (HKA), and overlap of long leg standing radiography (LLSR) obtained using a Rapid Orthoroentgenography Making Machine (RAPTOR) compared with a standard X-ray generator. Methods: This observational study was conducted between July 2021 and August 2021, including patients diagnosed with primary knee osteoarthritis that underwent preoperative LLSR for total knee replacement. Three orthopedic surgeons blindly evaluated LLSR (fAMA, HKA, overlap of the femoral shaft) twice within one-month using the Visio program. Intra- and interobserver reliability and validity were analyzed. Results: Three evaluators assessed 30 LLSRs. The intraobserver agreement levels were -0.951–1.062° for fAMA, -10.338–11.076° for HKA, and -0.418–0.418 mm for overlap of RAPTOR, while for the standard X-ray generator the agreement levels were -1.359–1.114° for fAMA, 11.844–12.467° for HKA, and 0 mm for overlap. The intraclass correlation was 0.55–0.99 for all RAPTOR measurements and 0.56–0.99 for standard X-ray generator. The interobserver’s levels of agreement were -1.441–1.175° for fAMA, -7.453–7.475° for HKA, and -0.681–0.637 mm for overlap of RAPTOR, whereas those of the standard X-ray generator were -1.149–1.424° for fAMA, -4.789–6.171° for HKA, and 0 mm for overlap. The intraclass correlation was 0.69–0.97 for all RAPTOR measurements and 0.71–0.95 for the fAMA and HKA standard X-ray generator measurements. The mean and 95% limits of agreement of the comparison between RAPTOR and standard X-ray generator were -0.131° (-1.187, 0.925) for fAMA, -0.126° (-4.724, 4.471) for HKA, and 0.363 (-) mm for overlap. Only overlap was significantly different between the two methods (p=0.0243). Intraclass correlations between the two radiographic methods were 0.75 (0.63, 0.88) for fAMA and 0.93 (0.89, 0.97) for HKA. Conclusions: Estimation of fAMA, HKA, and overlap had moderate to excellent reliability and inter- and intra-rater reliabilities in both RAPTOR and standard X-ray generator. Only overlap was different between the two methods.

Publisher

The Royal College of Orthopaedic Surgeons of Thailand

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3