Author:
Allen L,MacKay C,Rigby M H,Trites J,Taylor S M
Abstract
AbstractObjectiveThe Harmonic Scalpel and Ligasure (Covidien) devices are commonly used in head and neck surgery. Parotidectomy is a complex and intricate surgery that requires careful dissection of the facial nerve. This study aimed to compare surgical outcomes in parotidectomy using these haemostatic devices with traditional scalpel and cautery.MethodA systematic review of the literature was performed with subsequent meta-analysis of seven studies that compared the use of haemostatic devices to traditional scalpel and cautery in parotidectomy. Outcome measures included: temporary facial paresis, operating time, intra-operative blood loss, post-operative drain output and length of hospital stay.ResultsA total of 7 studies representing 675 patients were identified: 372 patients were treated with haemostatic devices, and 303 patients were treated with scalpel and cautery. Statistically significant outcomes favouring the use of haemostatic devices included operating time, intra-operative blood loss and post-operative drain output. Outcome measures that did not favour either treatment included facial nerve paresis and length of hospital stay.ConclusionOverall, haemostatic devices were found to reduce operating time, intra-operative blood loss and post-operative drain output.
Publisher
Cambridge University Press (CUP)
Subject
Otorhinolaryngology,General Medicine
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献