Bacterial Colonization in Humidifying Cascade Reservoirs After 24 and 48 Hours of Continuous Mechanical Ventilation

Author:

Goularte Theresa A.,Manning Marie,Craven Donald E.

Abstract

AbstractWe evaluated levels of bacterial colonization in the humidifying cascade reservoirs of 466 mechanical ventilators; 326 reservoirs were cultured after 24 hours and 140 were cultured after 48 hours of continuous mechanical ventilation. Bacterial colonization was absent in 284 (87.1%) of the humidifier reservoirs sampled at 24 hours and 125 (89.3%) of the reservoirs cultured at 48 hours. Levels of bacterial colonization in the remaining humidifiers were low (<100 organisms/mL). The median temperature recorded in the reservoir fluid of 30 different ventilators was 50°C (range 40° to 60°C). In vitro seeding of reservoir fluid at 50°C with 106 organisms/mL of four different species of nosocomial gram-negative bacilli and Staphylococcus aureus demonstrated rapid killing of all five strains over a 6-hour incubation period, and no significant bacterial aerosols were detected. Rates and levels of bacteria in heated humidifier reservoirs are low and nosocomial pathogens survive poorly at the median reservoir temperature of 50°C. We conclude that the heated humidifier reservoir on a mechanical ventilator is an unlikely source of colonization or bacterial aerosols, and therefore it can be changed every 48 hours with the ventilator tubing.

Publisher

Cambridge University Press (CUP)

Subject

General Medicine

Reference19 articles.

1. Risk factors for pneumonia in patients receiving mechanical ventilation;Craven;Am Rev Respir Dis,1986

2. Bubbling Humidifiers Produce Microaerosols Which Can Carry Bacteria

3. Legionella pneumophila contamination of a hospital humidifier: Demonstration of aerosol transmission and subsequent subclinical infection in exposed guinea pigs;Zuraleff;Am Rev Respir Dis,1983

4. Pulmonary Function in Mechanically-Ventilated Patients during 24-Hour Use of a Hygroscopic Condensor Humidifier

5. The relationship between frequency of ventilator circuit change and infectious hazard;Lareau;Am Rev Respir Dis,1978

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献