Abstract
The neutral beam (NB) fast ion confinement in the Large Helical Device (LHD) is studied for several full field (
$B_{t}\sim 2.75~\text{T}$
) magnetic configurations by a combination of neutron measurement and simulations. To investigate the NB fast ion confinement, we have performed a series of short-pulse NB injection experiments. The experiment results are analysed by the integrated code TASK3D-a. From this investigation, the effective particle diffusion coefficients of the tangential and perpendicular NBs are approximately
$D^{\text{eff}}\sim 0.1~\text{m}^{2}~\text{s}^{-1}$
and
$D^{\text{eff}}\sim 1~\text{m}^{2}~\text{s}^{-1}$
in the standard configuration. It is clarified that the NB fast ion confinement improves when the plasmas are shifted inward. Moreover, it is also found that the simulation, which considers the deuteron dilution effect due to the presence of impurity ions, can describe a neutron emission rate consistent with the measurement.
Publisher
Cambridge University Press (CUP)
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献