Author:
Sharma Archana,Mitra S.,Vishnu Sharma Senthil K.,Singh Sandeep,Tewari S.V.,Mittal K.C.
Abstract
AbstractThis paper elaborates the effect of unmatched stored energy in high-voltage high-energy pulsed power systems. High-voltage insulation failure of KALI system is analyzed thoroughly for its occurrence. According to the simulations and analysis energy mismatch of MARX generator and Blumlein transmission line is found to be the most significant cause for high-voltage failure of the system. MARX generator and Blumlein of KALI are redesigned to attain better energy balance at same voltage level. Observations, simulation and analytical results are illustrated in the following sections.
Subject
Electrical and Electronic Engineering,Condensed Matter Physics,Atomic and Molecular Physics, and Optics
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献