Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model

Author:

Jebb Susan A.,Cole Timothy J.,Doman Deanne,Murgatroyd Peter R.,Prentice Andrew M.

Abstract

The Tanita body-fat analyser is a novel device to estimate body fat, based on the principles of bioelectrical impedance. It differs from other impedance systems which use surface electrodes in that the subjects stand bare-footed on a metal sole-plate which incorporates the electrodes, hence impedance is measured through the legs and lower trunk. In 104 men and 101 women (16–78 years and BMI 16–41 kg/m2) the mean bias in body-fat mass measured using the Tanita body-fat analyser was 0·8 (2SD 7·9) KG RELATIVE TO A FOUR-COMPARTMENT MODEL. THIS IS COMPARABLE TO THE OTHER PREDICTION TECHNIQUES TESTED (CONVENTIONAL TETRAPOLAR IMPEDANCE -1·3 (2sd 6·9) kg, skinfold thicknesses 0·3 (2sd 7·4) kg, and BMI-based formulas -0·2 (2sd 9·0) kg and -0·6 (2sd 8·5) kg), but the agreement was poorer than for ‘reference’ methods to measure body fat (density 0·2 (2sd 3·7) kg, total body water -0·9 (2sd 3·4) kg and dual-energy X-ray absorptiometry 0·1 (2sd 5·0) kg). The present paper also describes the derivation of a new prediction equation for the calculation of body composition from the Tanita body-fat analyser. The equation incorporates sex, age, and a log-transformation of height, weight and the measured impedance to predict body fat measured by a four-compartment model. This approach is recommended in the derivation of other prediction equations in body composition analysis. Using this novel prediction equation the residual standard deviations were 4·8 % for men and 3·3 % for women. A similar analysis using data collected with a conventional tetrapolar system yielded residual standard deviations of 4·3 % for men and 3·1 % for women. This demonstrates that the practical simplicity of the novel Tanita method is not associated with a clinically significant decrement in performance relative to a traditional impedance device.

Publisher

Cambridge University Press (CUP)

Subject

Nutrition and Dietetics,Medicine (miscellaneous)

Reference17 articles.

1. Potential use of the bio-electrical impedance of the 'whole-body' and of body segments for the assessment of body composition: comparison with densitometry and anthropometry;Fuller;European Journal of Clinical Nutrition,1989

2. Measurement of soft tissue composition by dual energy X-ray absorptiometry

3. The Gross Composition of the Body

4. Multi-compartment models for the assessment of body composition in health and disease

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3