Author:
Fennema Peter,Heyse Thomas J.,Uyl-de Groot Carin A.
Abstract
Background:Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA). Advanced bearings are therefore required in TKA to reduce or eliminate wear-related loosening. A recently introduced bearing that combines oxidized zirconium with highly cross-linked PE has been shown to drastically reduce wear inin vitrosettings, due to its improved tribological characteristics in both tibial and femoral components. However, there are no data on its cost-effectiveness.Data and Methods:A Markov model was developed to assess the cost-effectiveness of this low-wear bearing from a German societal perspective. The model population was derived from a registry of 75,000 patients requiring TKA. The model allocated patients to receive either a low-wear or standard articulation, and followed them until death. Revisions and re-revision were included. Input values were derived from registry databases or from published reports in the literature. Threshold analysis and probabilistic sensitivity analysis were conducted to estimate model robustness.Results:The low-wear articulation prevented 24 (2.4 percent) revisions and 8 (0.8 percent) re-revisions. The total incremental cost-effectiveness ratio (ICER) of the low-wear articulation was EUR 16,474 per quality-adjusted life-year (QALY). For patients aged less than 55 years, an ICER of EUR 653 per QALY was observed. For patients aged over 75 years, this value was EUR 83,300. Threshold and probabilistic sensitivity analysis indicated that these findings were reasonably robust.Conclusion:Low-wear articulations may be considered cost-effective, although the cost effectiveness is age-dependent, with the cost per QALY being significantly lower for younger people than for older people.
Publisher
Cambridge University Press (CUP)
Reference41 articles.
1. CURRENT STATUS OF REVISION TOTAL KNEE ARTHROPLASTY
2. Federal Statistical Office of Germany. Life table for Germany. www.destatis.de/jetspeed/portal/cms/Sites/destatis/Internet/EN/Navigation/Statistics/Bevoelkung/GeburtenSterbefaelle/Tabellen.psml (accessed August 2010).
3. Isolation and characterization of debris in membranes around total joint prostheses.
4. Magazin Deutschland. Germany ranks seventh in Europen labor costs comparison for 2010. www.magazin-deutschland.de/en/article/article/deutschland-liegt-bei-arbeitskosten-im-europaeischen-mittelfeld.html (accessed December 2011).
5. Smith & Nephew Inc. VERILAST technology for knees. Global.smith-nephew.com/us/12146.htm (accessed November 2011).
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献