Author:
Rigby A.,Katz J.,Bott A. F. A.,White T. G.,Tzeferacos P.,Lamb D. Q.,Froula D. H.,Gregori G.
Abstract
Magnetic field measurements in turbulent plasmas are often difficult to perform. Here we show that for ${\geqslant}$kG magnetic fields, a time-resolved Faraday rotation measurement can be made at the OMEGA laser facility. This diagnostic has been implemented using the Thomson scattering probe beam and the resultant path-integrated magnetic field has been compared with that of proton radiography. Accurate measurement of magnetic fields is essential for satisfying the scientific goals of many current laser–plasma experiments.
Publisher
Cambridge University Press (CUP)
Subject
Nuclear Energy and Engineering,Nuclear and High Energy Physics,Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials
Cited by
6 articles.