Left-sided breast radiotherapy after conservative surgery: comparison of techniques between volumetric modulated arc therapy, forward-planning intensity-modulated radiotherapy and conventional technique

Author:

Giri Upendra Kumar,Sarkar Biplab,Jassal Kanan,Munshi Anusheel,Ganesh Tharmar,Mohanti Bidhu,Pradhan Anirudh

Abstract

AbstractObjectiveThis study was conducted for comparison of techniques between volumetric modulated arc therapy (VMAT), forward-planning intensity-modulated radiotherapy (FIMRT) and conventional technique for left-sided breast radiotherapy after conservative surgery.MethodsIn all, 20 postoperative left breast carcinoma patients were included in this study. In all plans the planning target volume (PTV) was the breast tissue with appropriate margin as per our institutional protocol. The contouring was done on a Monaco Sim (V5.00.02) contouring workstation. All patient were planned using partial arc VMAT in Monaco treatment planning system (TPS) (V5.00.02) and treated on Elekta Synergy linear accelerator. The 3D conformal radiotherapy (3DCRT) and FIMRT planning were done in CMS XIO (V5.00.01.1) TPS. The 3DCRT planning consisted of conventional medial and tangential wedge portals with multileaf collimator field shaping conforming to the target volume. For all the plans generated the following metrics were scored: V105%, V100%, V95%, mean dose (for PTV), V5%, V20%, D2cc and mean dose (for organs at risk).ResultsThe mean PTV volume for 20 patients was 1,074·6±405·1 cc. The highest PTV dose coverage was observed in the 3DCRT technique with 94·1±1·8% of the breast PTV receiving 95% of the prescription dose (V95%). However, it was also observed that this technique resulted in 21·3±10% of the PTV receiving more than 105% of the prescription dose (V105%), which was highest among the three techniques. In contrast, VMAT yielded lowest V95% of 93·0±1·8 and 3·3±5·5% of V105%.ConclusionThis study concluded equivalent result between FIMRT and VMAT. However, VMAT was found to be the choice of radiotherapy technique as it produces lesser dose distribution to heart compared with any other technique.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3