Characterising intensity-modulated radiation therapy (IMRT) software following upgrades in a commercial treatment planning system

Author:

McGarry Connor,O’Toole Monica,Cosgrove Vivian

Abstract

AbstractWhen upgrading treatment planning software, it is important to understand and characterise any changes that may have been made to the system. This includes inverse treatment planning and dose optimisation software used for intensity-modulated radiation therapy (IMRT). A systematic and practical approach to characterising dose optimisation software following upgrades is presented based on a planning study of six IMRT prostate cases using the commercial treatment planning system Oncentra Masterplan (OMP). Upgrades included general changes in the fluence to multileaf collimator (MLC) segmentation algorithm, a change from a two-step to a one-step optimisation method and an upgrade of the dose calculation algorithm. Post upgrade changes in plan parameters such as calculation times, monitor units, segments and target doses were analysed. A 32% reduction in total calculated monitor units was observed following the general software upgrade. A smaller 12% reduction was observed when using the optional one-step optimisation method rather than a two-step process using a classic dose calculation algorithm. An increase in monitor units of approximately 12% was observed when changing to an enhanced dose calculation algorithm. The enhanced dose calculation algorithm accounted for MLC type, leakage and source size unlike the previous classic dose calculation algorithm. Differences in dose to volumes between fluence segmentation and final dose calculation varied between versions. These differences were found to be minimal for the most recent treatment planning system version. Repeatability tests revealed a more effective use of the system. The characterisation of the effects of treatment planning software upgrades allowed a better appreciation of IMRT planning and delivery attributes. Although this work is based on one commercial inverse treatment planning system, it would be easily transferable to other systems as the underlying system principles are the same.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3