Comparison of test performance of two commonly used multiplex assays to measure micronutrient and inflammatory markers in serum: results from a survey among pregnant women in South Africa

Author:

Chimhashu Tsitsi LetwinORCID,Verhoef Hans,Symington Elizabeth A.,Zandberg Lizelle,Baumgartner Jeannine,Malan Linda,Smuts Cornelius MariusORCID,Feskens Edith J. M.ORCID,Melse-Boonstra AlidaORCID

Abstract

AbstractThe combined sandwich-ELISA (s-ELISA; VitMin Lab, Germany) and the Quansys Q-Plex™ Human Micronutrient Array (7-Plex) are multiplex serum assays that are used to assess population micronutrient status in low-income countries. We aimed to compare the agreement of five analytes, α-1-acid glycoprotein (AGP), C-reactive protein (CRP), ferritin, retinol-binding protein 4 (RBP4) and soluble transferrin receptor (sTfR) as measured by the 7-Plex and the s-ELISA. Serum samples were collected between March 2016 and December 2017. Pregnant women (n 249) were recruited at primary healthcare clinics in Johannesburg, and serum samples were collected between March 2016 and December 2017. Agreement between continuous measurements was assessed by Bland–Altman plots and concordance measures. Agreement in classifications of deficiency or inflammation was assessed by Cohen’s kappa. Strong correlations (r > 0·80) were observed between the 7-Plex and s-ELISA for CRP and ferritin. Except for CRP, the 7-Plex assay gave consistently higher measurements than the s-ELISA. With the exception of CRP (Lin’s ρ = 0·92), there was poor agreement between the two assays, with Lin’s ρ < 0·90. Discrepancies of test results difference between methods increased as the serum concentrations rose. Cohen’s kappa for all the five analytes was < 0·81 and ranged from slight agreement (vitamin A deficiency) to substantial (inflammation and Fe deficiency) agreement. The 7-Plex 1.0 is a research and or surveillance tool with potential for use in low-resource laboratories but cannot be used interchangeably with the s-ELISA. Further optimising and validation is required to establish its interchangeability with other validated methods.

Publisher

Cambridge University Press (CUP)

Subject

Nutrition and Dietetics,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Assessment of iron status;Current Opinion in Clinical Nutrition & Metabolic Care;2024-06-07

2. Nutrition in chronic inflammatory conditions: Bypassing the mucosal block for micronutrients;Allergy;2023-12-12