Direct numerical simulation of stenotic flows. Part 1. Steady flow

Author:

VARGHESE SONU S.,FRANKEL STEVEN H.,FISCHER PAUL F.

Abstract

Direct numerical simulations (DNS) of steady and pulsatile flow through 75% (by area reduction) stenosed tubes have been performed, with the motivation of understanding the biofluid dynamics of actual stenosed arteries. The spectral-element method, providing geometric flexibility and high-order spectral accuracy, was employed for the simulations. The steady flow results are examined here while the pulsatile flow analysis is dealt with in Part 2 of this study. At inlet Reynolds numbers of 500 and 1000, DNS predict a laminar flow field downstream of an axisymmetric stenosis and comparison to previous experiments show good agreement in the immediate post-stenotic region. The introduction of a geometric perturbation within the current model, in the form of a stenosis eccentricity that was 5% of the main vessel diameter at the throat, resulted in breaking of the symmetry of the post-stenotic flow field by causing the jet to deflect towards the side of the eccentricity and, at a high enough Reynolds number of 1000, jet breakdown occurred in the downstream region. The flow transitioned to turbulence about five diameters away from the stenosis, with velocity spectra taking on a broadband nature, acquiring a -5/3 slope that is typical of turbulent flows. Transition was accomplished by the breaking up of streamwise, hairpin vortices into a localized turbulent spot, reminiscent of the turbulent puff observed in pipe flow transition, within which r.m.s. velocity and turbulent energy levels were highest. Turbulent fluctuations and energy levels rapidly decayed beyond this region and flow relaminarized. The acceleration of the fluid through the stenosis resulted in wall shear stress (WSS) magnitudes that exceeded upstream levels by more than a factor of 30 but low WSS levels accompanied the flow separation zones that formed immediately downstream of the stenosis. Transition to turbulence in the case of the eccentric stenosis was found to be manifested as large temporal and spatial gradients of shear stress, with significant axial and circumferential variations in instantaneous WSS.

Publisher

Cambridge University Press (CUP)

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics

Cited by 164 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3