Comparison of Monitoring Techniques for Intraoperative Cerebral Ischemia

Author:

Rowed David W.,Houlden David A.,Burkholder Lee M.,Taylor Amanda B.

Abstract

Objective:To prospectively compare somatosensory evoked potentials, electroencephalography (EEG) and transcranial Doppler ultrasound (TCD) for detection of cerebral ischemia during carotid endarterectomy (CEA).Methods:Somatosensory evoked potentials and EEG recordings were attempted in 156 consecutive CEAs and TCD was also attempted in 91 of them. Recordings from all three modalities were obtained for at least 10 minutes before CEA, during CEAand for at least 15 minutes after CEA. Somatosensory evoked potentials peak-to-peak amplitude decrease of >50%, EEG amplitude decrease of >75%, and ipsilateral middle cerebral artery mean blood flow velocity (mean VMCAi) decrease >75% persisting for the entire period of internal carotid artery occlusion were individually considered to be diagnostic of cerebral ischemia. Clinical neurological examination was performed immediately prior to surgery and following recovery from general anaesthesia.Results:Somatosensory evoked potentials, EEG, and TCD were successfully obtained throughout the entire period of internal carotid artery occlusion in 99%, 95%, and 63% of patients respectively. Two patients (1.3%) suffered intraoperative cerebral infarction detected by clinical neurological examination and subsequent magnetic resonance imaging. Somatosensory evoked potentials accurately predicted intraoperative cerebral infarction in both instances without false negatives or false positives, EEG yielded one false negative result and no false positive results and VMCAi one true positive, four false positive and no false negative results. Transcranial Doppler ultrasound detection of emboli did not correlate with postoperative neurological deficits. Nevertheless the sensitivity and specificity of each test was not significantly different than the others because of the small number of disagreements between tests.Conclusion:A >50% decrease in the cortically generated P25 amplitude of the median somatosensory evoked potentials, which persisted during the entire period of internal carotid artery occlusion, appears to be the most reliable method of monitoring for intraoperative ischemia in our hands because it accurately detected both intraoperative strokes with no false positive or false negative results.

Publisher

Cambridge University Press (CUP)

Subject

Neurology (clinical),Neurology,General Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3