3D Conformal Radiotherapy and Cisplatin for Recurrent Malignant Glioma

Author:

VanderSpek Lauren,Fisher Barbara,Bauman Glenn,Macdonald David

Abstract

Purpose:To determine the maximum tolerated dose of 3D conformal radiotherapy in combination with Cisplatin for patients with recurrent malignant gliomas.Methods:From 1999-2003, nine patients with recurrent malignant glioma received fractionated radiotherapy and Cisplatin (20 mg/m2/d IV on days 1-5) in a Phase I radiation dose escalation trial. Three sequential dose levels were evaluated: 25 Gy, 30 Gy, and 35 Gy, using 5 Gy fractions. All patients received prior external beam radiation (median dose 59.4 (20-60) Gy) and five patients received prior chemotherapy.Results:Six male and three female patients were enrolled with a median age of 52 years, and a median Karnofsky performance status score of 70. The median re-irradiated tumor volume was 18.9 (0.1-78.5) cm3 and the median follow-up was 8.8 (3.2-31.2) months. One patient (30 Gy/ 6 fractions) experienced medically reversible acute grade 3 toxicity. A second patient (35 Gy/ 7 fractions) experienced acute grade 2 toxicity and histology showed tumor and radiation effect. A third patient (25 Gy/ 5 fractions) experienced late grade 3 toxicity from radiation necrosis. The radiological responses consisted of complete response (1 patient), partial response (1 patient), and stable disease (2 patients). The median overall survival was 8.8 months (95% CI 8.0-9.9), and the median disease free interval was 2.0 months (95% CI 1.4-4.4). Seven patients received chemotherapy following re-irradiation and Cisplatin.Conclusion:The maximum tolerated dose of 3D conformal fractionated radiotherapy was 30 Gy in 6 fractions with low dose Cisplatin, which was well tolerated in terms of acute toxicity for our patient population. This regimen demonstrated only modest efficacy in the treatment of recurrent malignant glioma. Combinations of conformal re-irradiation and other systemic agents may merit investigation. Currently our recommended dose is 30 Gy in 6 fractions for selected patients.

Publisher

Cambridge University Press (CUP)

Subject

Clinical Neurology,Neurology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3