Bacteriological aspects of air-conditioning plants

Author:

Whyte W.

Abstract

An investigation was carried out into the bacteriological performance of three air-conditioning plants in a hospital ward. Two of these plants had the facility for recirculating part of the ward air.An equation has been derived comparing the concentration of bacteria which would be expected to be given off by the humidifiers in the ventilation system, with the concentration of bacteria in the recirculatory tank. The bacterial particles given off by these humidifiers were of nuclei droplet size, and were found to penetrate the filters used with a fair degree of ease. Although the number of bacteria in the humidifier water remained insignificant with a constant overflow of water into the recirculatory tank, on one occasion a build-up of bacteria was demonstrated when the overflow ceased. For hospital use humidifiers of a non-recirculatory type should be used.The concentration of bacteria on the surface of the recirculatory ducts was assessed, as also were those on the surface of the supply ducts under full fresh air and recirculation. The concentration of bacteria in the supply ducts was low and the use of terminal filters was not merited, although care should be taken to prevent the build-up of bacteria in inlet grills and diffusers. The bacterial concentration in the exhaust ducts was found to be quite high. It was therefore thought that in critical areas, where the ventilation plant may be shut off, the use of some device to prevent reversed air flow may be necessary.The count of various types of micro-organisms in the fresh air and two-thirds recirculated air are given along with their size distribution. The results of the effect of filtration on the concentration of bacterial particles throughout the air-conditioning plant is given under full fresh air and recirculation. These concentrations appear quite satisfactory. It was found that one set of filters had been overgrown by mould because of free water being brought over from the humidifier. Measures have been suggested to overcome this. When primary or prefinal filtration was approximately 90% efficient to Aloxite 50 (B.S. 2831 Test Dust no. 2) it was demonstrated that a fair approximation to the final filtration figure could be obtained by reference to the quoted efficiency of the final filter to Aloxite 50. After similar primary filtration it was demonstrated that the final filtration of filters against recirculated and fresh air was approximately the same. Owing to the higher number ofStaph. aureusin recirculated air, higher efficiency filtration may be required.Standards of filtration efficiency for critical and non-critical zones are suggested.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Epidemiology

Reference18 articles.

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Indoor Air Quality: A Review of Cleaning Technologies;Environments;2022-09-07

2. UV-C IŞINIMLI HAVA DEZENFEKSİYON CİHAZININ PATOJENLER ÜZERİNE ETKİSİNİN DENEYSEL OLARAK İNCELENMESİ;Mühendis ve Makina;2022-01-21

3. The design and testing of unidirectional airflow operating theatres;International Journal of Ventilation;2021-04-28

4. Sensory environment on health-related outcomes of hospital patients;Cochrane Database of Systematic Reviews;2012-03-14

5. Introduction;Ultraviolet Germicidal Irradiation Handbook;2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3