Transfer areas and clean zones in operating suites

Author:

Ayliffe G. A. J.,Babb J. R.,Collins B. J.,Lowbury E. J. L.

Abstract

SUMMARYThe value of clean zones and of transfer areas in operating suites was assessed by comparisons of the amounts of contamination on floors, trolleys and footwear in suites with and without a clean zone and a transfer area; counts of Clostridium welchii were used as an index of bacterial contamination introduced into the aseptic zone from outside.The mean counts of Cl. welchii on contact plates from the wheels of trolleys used to convey patients from wards to the operating suite (67·9 ± 7·68 per plate) were significantly higher than those from theatre trolleys (i.e. those used only inside a theatre suite provided with a transfer area) (3·13 ± 0·47 per plate); mean counts of total bacteria were only slightly lower on the wheels of theatre trolleys than on those of hospital trolleys. Other surfaces of hospital trolleys showed counts similar to those found on theatre trolleys.Contact plates from floors showed significantly lower counts of Cl. welchii in the aseptic zone and the clean zone than in the hospital corridor, the protective zone and (when present) the transfer area.The mean counts per 100 cm2 of Cl. welchii were approximately the same on the floor of a theatre with a clean zone and a transfer area (0·83) as in one with a clean zone but no transfer area (0·5). Counts of total bacteria were higher in the latter. A suite with no clean zone or transfer area showed a higher mean count of Cl. welchii on contact plates from the aseptic zone (operating theatre) (20·5 ± 12·33 per 100 cm2). These higher levels of contamination were due to sporadic high counts of Cl. welchii found near the door of the theatre with no clean zone; in another theatre with no clean zone the level of Cl. welchii on the floor was not higher than that in the theatres with clean zones.Theatres with plenum ventilation had lower mean counts of airborne Cl. welchii than those ventilated by windows: there was no significant difference in the levels of Cl. welchii on the floors of theatres with the two forms of ventilation.On sampling with contact plates, theatre footwear yielded fewer total organisms, Staphylococcus aureus and Cl. welchii than outdoor shoes removed before entering the clean zone.The hygienic value of transfer areas and clean zones is discussed. Bacteriological support could not be obtained for the former, but the latter appeared to contribute something to the cleanliness of the theatre by preventing heavy sporadic contamination.We wish to thank Mr M. Wilkins for valuable assistance, the staff of the operating theatres for their co-operation and Alne Engineering Limited, 57 High Street, Henley-in-Arden, Solihull, for supplying disposable contact plates.

Publisher

Cambridge University Press (CUP)

Subject

Public Health, Environmental and Occupational Health,Immunology

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Rituals and behaviours in the operating theatre – joint guidelines of the Healthcare Infection Society and the European Society of Clinical Microbiology and Infectious Diseases;Journal of Hospital Infection;2023-10

2. Rituals versus risks in the contemporary operating theatre environment;British Journal of Theatre Nursing (United Kingdom);1999-08

3. Asepsis in Operating Theatres;Control of Hospital Infection;1998

4. Bauliche Maßnahmen;Praktische Krankenhaushygiene und Umweltschutz;1992

5. Why isolate theatre suites?;The Lancet;1991-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3