Author:
Xu Xiaomei,Gao Pan,Salamanca Eric G
Abstract
A modified sealed tube Zn reduction method based on Khosh et al. (2010) has been developed to graphitize ultra small-mass samples ranging from 4–15 μg carbon (C) for accelerator mass spectrometry (AMS) radiocarbon measurements. In this method, the reagent TiH2 is removed from the previous method while the amounts of Zn and Fe powder remain the same. The volume of the sealed reactor is further reduced by ∼40% to ∼0.75 cm3 and the graphitization temperature is lowered to 450 °C. Graphite targets produced by this method generally yield 12C+1 currents of about 0.5 μA per 1 μg C, similar to the small mass (15–100 μg C) sealed tube Zn reduction method previously reported by Khosh et al. (2010) when measured on the same AMS system at KCCAMS, University of California, Irvine. Change of Fe powder to Sigma-Aldrich (400-mesh) has yielded further improved backgrounds over Fe powder of Alfa Aesar (325-mesh). Modern C background from combustion and graphitization is estimated to be 0.2–0.8 μg C, and dead-C background to be 0.1–0.4 μg C. The accuracy and precision of ultra small-mass samples prepared by this method are size and 14C content dependent, but is usually ±4–5% for the smallest sample size of ∼4–5 μg C with modern 14C content. AMS on-line δ13C measurement that allows for correction of both graphitization and machine-induced isotopic fractionation is the key for applying the sealed tube Zn reduction method to ultra small-mass sample graphitization.
Publisher
Cambridge University Press (CUP)
Subject
General Earth and Planetary Sciences,Archeology
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献