Author:
Marzaioli F,Borriello G,Passariello I,Lubritto C,Cesare N De,D'Onofrio A,Terrasi F
Abstract
The pretreatment of samples for radiocarbon measurements, transforming a variety of materials into graphite solid targets, represents a critical point in the accelerator mass spectrometry (AMS) procedure. We describe the new, state-of-the-art CIRCE AMS preparation laboratory, particularly the setup and optimization of an alternative method, the zinc reduction method, for graphite target production, compared to the more common hydrogen reduction method. Measured 14C values on standard and blank samples reduced via zinc reaction revealed mean background levels, accuracy, and sensitivity comparable to those obtained by our conventional hydrogen reaction lines. Zinc line reduction at the CIRCE laboratory represents an effective and powerful alternative to the conventional hydrogen reduction, ensuring higher sample throughput with lower costs at a comparable performance level.
Publisher
Cambridge University Press (CUP)
Subject
General Earth and Planetary Sciences,Archaeology
Cited by
72 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献