Abstract

Background.Measurement of central line-associated bloodstream infection (CLABSI) rates outside of intensive care units is challenged by the difficulty in reliably determining central venous catheter (CVC) use. The National Healthcare Safety Network (NHSN) allows for use of electronic data for determination of CVC-days, but validation of electronic data has not been studied systematically.Objective.To design and validate a process to reliably measure CVC-days outside of the intensive care units that leverages electronic documentation.Methods.Thirty-four inpatient wards at 2 academic hospitals using a common electronic platform for nursing documentation were studied. Electronic queries were created to capture patient and CVC information, and tools and processes for tracking and reporting errors in documentation were developed. Strategies to validate electronic data included comparisons with manual CVC-day determinations and automated data validation using customized tools. Interventions included redesign of documentation interface, real-time audit with feedback of errors, and education. The primary outcome was patient-level total error rate in electronic CVC-day measurement compared with manually counted CVC-days.Results.At baseline, there were a mean (± standard deviation) of 0.32 ± 0.25 electronic CVC-day errors (omission and commission errors summed and counted equally) per manually counted CVC-day. After several process improvement cycles over 7 months, the error rate decreased to <0.05 errors per CVC-day and remained at or below this level for 2 years.Conclusions.Baseline electronic CVC-day counts had a high error rate. Stepwise interventions reduced errors to consistently low levels. Validation of electronic calculation of CVC-days is essential to ensure accuracy, particularly if these data will be used for interinstitutional comparison.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Reference10 articles.

1. Maintaining vascular access devices: the nurse's role

2. Infusion Nurses Society. Nursing standards of practice;J Infus Nurs,20ll

3. Electronic Algorithmic Prediction of Central Vascular Catheter Use

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3