Author:
Bryunetkin B. A.,Pikuz S. A.,Skobelev I. Y.,Faenov A. Y.
Abstract
The imaging spectrograph with spherical crystal and transmission grating have been used to obtain the high spectrally and spatially resolved images of plasma X-ray microsources (fast z-pinch) as well as of laser-produced plasma flares up to 5 mm in extent. The spectral resolution λ/Δλ = 2·104 have been achieved using a quartz spherical mirror with the curvature radius 500 mm. Using a transmission grating spectrometer, the spectral density of power about 105 W/A in the “water window” has been measured in experiments with a fast z-pinch large pulse storage facility.
Subject
Electrical and Electronic Engineering,Condensed Matter Physics,Atomic and Molecular Physics, and Optics
Cited by
23 articles.
订阅此论文施引文献