Molecular analysis of bacterial contamination on stethoscopes in an intensive care unit

Author:

Knecht Vincent R.,McGinniss John E.,Shankar Hari M.,Clarke Erik L.,Kelly Brendan J.,Imai Ize,Fitzgerald Ayannah S.,Bittinger Kyle,Bushman Frederic D.ORCID,Collman Ronald G.

Abstract

AbstractBackgroundCulture-based studies, which focus on individual organisms, have implicated stethoscopes as potential vectors of nosocomial bacterial transmission. However, the full bacterial communities that contaminate in-use stethoscopes have not been investigated.MethodsWe used bacterial 16S rRNA gene deep-sequencing, analysis, and quantification to profile entire bacterial populations on stethoscopes in use in an intensive care unit (ICU), including practitioner stethoscopes, individual-use patient-room stethoscopes, and clean unused individual-use stethoscopes. Two additional sets of practitioner stethoscopes were sampled before and after cleaning using standardized or practitioner-preferred methods.ResultsBacterial contamination levels were highest on practitioner stethoscopes, followed by patient-room stethoscopes, whereas clean stethoscopes were indistinguishable from background controls. Bacterial communities on stethoscopes were complex, and community analysis by weighted UniFrac showed that physician and patient-room stethoscopes were indistinguishable and significantly different from clean stethoscopes and background controls. Genera relevant to healthcare-associated infections (HAIs) were common on practitioner stethoscopes, among which Staphylococcus was ubiquitous and had the highest relative abundance (6.8%–14% of contaminating bacterial sequences). Other HAI-related genera were also widespread although lower in abundance. Cleaning of practitioner stethoscopes resulted in a significant reduction in bacterial contamination levels, but these levels reached those of clean stethoscopes in only a few cases with either standardized or practitioner-preferred methods, and bacterial community composition did not significantly change.ConclusionsStethoscopes used in an ICU carry bacterial DNA reflecting complex microbial communities that include nosocomially important taxa. Commonly used cleaning practices reduce contamination but are only partially successful at modifying or eliminating these communities.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Reference24 articles.

1. Rutala WA , Weber DJ , and the Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. Center for Disease Control website. https://www.cdc.gov/infectioncontrol/pdf/guidelines/disinfection-guidelines.pdf. Published 2017. Accessed November 21, 2018.

2. Allometry and Ecology of the Bilaterian Gut Microbiome

3. Development of a Dual-Index Sequencing Strategy and Curation Pipeline for Analyzing Amplicon Sequence Data on the MiSeq Illumina Sequencing Platform

4. Contamination of Stethoscopes and Physicians' Hands After a Physical Examination

5. Reagent and laboratory contamination can critically impact sequence-based microbiome analyses

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3