Right ventricular outflow tract landing zone perimeter / circularised diameter – new imaging standards in pulmonary valve replacement reporting

Author:

Ligon R. AllenORCID,Latson Larry A.,Ruzmetov Mark M.,Hernandez Lazaro E.ORCID

Abstract

Abstract Background: Right ventricular outflow tract intervention spans transcatheter, surgical, or hybrid pulmonary valve replacement methodologies. Standardised pre-procedure workup includes cardiac MRI to identify an intended valve site (landing zone). Our institutional practice includes measurement of the right ventricular outflow tract perimeter (circumference) of this site in end-systole. Our primary aim was to compare patients by their perimeter values to the palliative interventions performed (transcatheter versus surgical/hybrid methodologies). Methods: Retrospective review of patients undergoing pulmonary valve replacement from January 2017 to 2021. We performed perimeter measurements at the intended valve site on advanced imaging; the outcomes of interventions were outlined via descriptive and statistical analyses. Results: A total of 37 patients underwent pulmonary valve replacement that met study criteria – 21 transcatheter, 7 surgical, and 9 hybrid. Median age at intervention was 26 years (range 8–70). The mean end-systolic perimeter of the transcatheter cohort was 88.9 ± 8.7 mm and in the surgical/hybrid cohort measured 106.6 ± 7.5 mm. For the transcatheter cohort, the median “circularised” diameter derived from the perimeter measurement (divided by π) was 27.7 mm (range 24.3–32.4). Notably, this correlated (r = 0.93, p < 0.01) with the median diameter of the narrowest region during actual transcatheter right ventricular outflow tract balloon sizing (lateral imaging) of 27.1 mm (range 23.2–30.1). Conclusions: Right ventricular outflow tract perimeter measurement to determine circularised diameter is useful in planning pulmonary valve replacement in terms of candidacy of transcatheter versus the need for a surgical/hybrid approach. The circularised diameter correlates with transcatheter right ventricular outflow tract balloon sizing.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3