Usefulness of maximal oxygen pulse in timing of pulmonary valve replacement in patients with isolated pulmonary regurgitation

Author:

Legendre Antoine,Richard Ruddy,Pontnau Florence,Jais Jean-Philippe,Dufour Marc,Grenier Olivier,Mousseaux Elie,Ladouceur Magalie,Iserin Laurence,Bonnet Damien

Abstract

Patients with pulmonary regurgitation after tetralogy of Fallot repair have impaired aerobic capacity; one of the reasons is the decreasing global ventricular performance at exercise, reflected by decreasing peak oxygen pulse. The aims of our study were to evaluate the impact of pulmonary valve replacement on peak oxygen pulse in a population with pure pulmonary regurgitation and with different degrees of right ventricular dilatation and to determine the predictors of peak oxygen pulse after pulmonary valve replacement.The mean and median age at pulmonary valve replacement was 27 years. Mean pre-procedural right ventricular end-diastolic volume was 182 ml/m2. Out of 24 patients, 15 had abnormal peak oxygen pulse before pulmonary valve replacement. We did not observe a significant increase in peak oxygen pulse after pulmonary valve replacement (p=0.76). Among cardiopulmonary test/MRI/historical pre-procedural parameters, peak oxygen pulse appeared to be the best predictor of peak oxygen pulse after pulmonary valve replacement (positive and negative predictive values, respectively, 0.94 and 1). After pulmonary valve replacement, peak oxygen pulse was well correlated with left ventricular stroke and end-diastolic volumes (r=0.67 and 0.68, respectively).Our study confirms the absence of an effect of pulmonary valve replacement on peak oxygen pulse whatever the initial right ventricular volume, reflecting possible irreversible right and/or left ventricle lesions. Pre-procedural peak oxygen pulse seemed to well predict post-procedural peak oxygen pulse. These results encourage discussions on pulmonary valve replacement in patients showing any decrease in peak oxygen pulse during their follow-up.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3