Technical factors are associated with complications and repeat intervention in neonates undergoing transcatheter right ventricular decompression for pulmonary atresia and intact ventricular septum: results from the congenital catheterisation research collaborative

Author:

Petit Christopher J.,Qureshi Athar M.,Glatz Andrew C.,Kelleman Michael S.,McCracken Courtney E.,Ligon R. Allen,Mozumdar Namrita,Whiteside Wendy,Khan Asra,Goldstein Bryan H.

Abstract

AbstractBackgroundTranscatheter right ventricle decompression in neonates with pulmonary atresia and intact ventricular septum is technically challenging, with risk of cardiac perforation and death. Further, despite successful right ventricle decompression, re-intervention on the pulmonary valve is common. The association between technical factors during right ventricle decompression and the risks of complications and re-intervention are not well described.MethodsThis is a multicentre retrospective study among the participating centres of the Congenital Catheterization Research Collaborative. Between 2005 and 2015, all neonates with pulmonary atresia and intact ventricular septum and attempted transcatheter right ventricle decompression were included. Technical factors evaluated included the use and characteristics of radiofrequency energy, maximal balloon-to-pulmonary valve annulus ratio, infundibular diameter, and right ventricle systolic pressure pre- and post-valvuloplasty (BPV). The primary end point was cardiac perforation or death; the secondary end point was re-intervention.ResultsA total of 99 neonates underwent transcatheter right ventricle decompression at a median of 3 days (IQR 2–5) of age, including 63 patients by radiofrequency and 32 by wire perforation of the pulmonary valve. There were 32 complications including 10 (10.5%) cardiac perforations, of which two resulted in death. Cardiac perforation was associated with the use of radiofrequency (p=0.047), longer radiofrequency duration (3.5 versus 2.0 seconds, p=0.02), and higher maximal radiofrequency energy (7.5 versus 5.0 J, p<0.01) but not with patient weight (p=0.09), pulmonary valve diameter (p=0.23), or infundibular diameter (p=0.57). Re-intervention was performed in 36 patients and was associated with higher post-intervention right ventricle pressure (median 60 versus 50 mmHg, p=0.041) and residual valve gradient (median 15 versus 10 mmHg, p=0.046), but not with balloon-to-pulmonary valve annulus ratio, atmospheric pressure used during BPV, or the presence of a residual balloon waist during BPV. Re-intervention was not associated with any right ventricle anatomic characteristics, including pulmonary valve diameter.ConclusionTechnical factors surrounding transcatheter right ventricle decompression in pulmonary atresia and intact ventricular septum influence the risk of procedural complications but not the risk of future re-intervention. Cardiac perforation is associated with the use of radiofrequency energy, as well as radiofrequency application characteristics. Re-intervention after right ventricle decompression for pulmonary atresia and intact ventricular septum is common and relates to haemodynamic measures surrounding initial BPV.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3