Echocardiographic diagnosis of partial obstruction of Blalock-Taussig shunts
-
Published:2002-03
Issue:2
Volume:12
Page:189-191
-
ISSN:1047-9511
-
Container-title:Cardiology in the Young
-
language:en
-
Short-container-title:Cardiol Young
Author:
Juraszek Amy L.,Atz Andrew M.,Shirali Girish S.
Abstract
While echocardiography has previously been used to differentiate between patency and complete occlusion of aortopulmonary shunts, the echocardiographic diagnosis of partial obstruction of a shunt has not been reported. We describe a unique color flow Doppler finding that quickly and accurately diagnosed three cases of partial distal obstruction of aortopulmonary shunts.
Publisher
Cambridge University Press (CUP)
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Echocardiography in the ICU;Pediatric and Congenital Cardiology, Cardiac Surgery and Intensive Care;2020
2. Echocardiography in the ICU;Pediatric and Congenital Cardiology, Cardiac Surgery and Intensive Care;2013-09-18
3. Bleeding and Thrombotic Emergencies in Pediatric Cardiac Intensive Care;World Journal for Pediatric and Congenital Heart Surgery;2012-10
4. Accordion-Like Prosthesis for Modified Blalock-Taussig Shunt;Asian Cardiovascular and Thoracic Annals;2003-09