Comparison of echocardiographic measurements to invasive measurements of diastolic function in infants with single ventricle physiology: a report from the Pediatric Heart Network Infant Single Ventricle Trial

Author:

Goudar Suma P.ORCID,Zak VictorORCID,Atz Andrew M.,Altmann Karen,Colan Steven D.,Falkensammer Christine B.,Friedberg Mark K.,Frommelt Michele,Hill Kevin D.,Hsu Daphne T.,Levine Jami C.,Margossian Renee,Mart Christopher R.,Sticka Joshua,Shrader Peter,Shirali Girish,

Abstract

AbstractBackground:While echocardiographic parameters are used to quantify ventricular function in infants with single ventricle physiology, there are few data comparing these to invasive measurements. This study correlates echocardiographic measures of diastolic function with ventricular end-diastolic pressure in infants with single ventricle physiology prior to superior cavopulmonary anastomosis.Methods:Data from 173 patients enrolled in the Pediatric Heart Network Infant Single Ventricle enalapril trial were analysed. Those with mixed ventricular types (n = 17) and one outlier (end-diastolic pressure = 32 mmHg) were excluded from the analysis, leaving a total sample size of 155 patients. Echocardiographic measurements were correlated to end-diastolic pressure using Spearman’s test.Results:Median age at echocardiogram was 4.6 (range 2.5–7.4) months. Median ventricular end-diastolic pressure was 7 (range 3–19) mmHg. Median time difference between the echocardiogram and catheterisation was 0 days (range −35 to 59 days). Examining the entire cohort of 155 patients, no echocardiographic diastolic function variable correlated with ventricular end-diastolic pressure. When the analysis was limited to the 86 patients who had similar sedation for both studies, the systolic:diastolic duration ratio had a significant but weak negative correlation with end-diastolic pressure (r = −0.3, p = 0.004). The remaining echocardiographic variables did not correlate with ventricular end-diastolic pressure.Conclusion:In this cohort of infants with single ventricle physiology prior to superior cavopulmonary anastomosis, most conventional echocardiographic measures of diastolic function did not correlate with ventricular end-diastolic pressure at cardiac catheterisation. These limitations should be factored into the interpretation of quantitative echo data in this patient population.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3