Pulmonary effects on exercise testing in tetralogy of Fallot patients repaired with a transannular patch

Author:

Powell Adam W.ORCID,Mays Wayne A.,Knecht Sandra K.,Chin Clifford

Abstract

AbstractBackgroundA transannular patch is often used in the contemporary surgical repair of tetralogy of Fallot. This can lead to significant pulmonary insufficiency and increased right ventricular volumes and ultimately pulmonary valve replacement. Cardiopulmonary exercise testing is used to assess exercise capacity in tetralogy of Fallot patients before pulmonary valve replacement. There is only few published literatures on how lung function affects functional capacity in tetralogy of Fallot patients repaired with a transannular patch.MethodsA retrospective chart review was done from 2015 to 2017 on patients with tetralogy of Fallot who underwent maximal effort cardiopulmonary exercise testing with cycle ergometry and with concurrent pulmonary function testing. Tetralogy of Fallot patients repaired with a transannular patch without pulmonary valve replacement were compared with age, gender, and size-matched normal controls.ResultsIn the tetralogy of Fallot group, 24 out of 57 patients underwent primary repair with a transannular patch. When compared to the normal controls, they demonstrated abnormal predicted forced expiratory volume in one second (79 ± 23.1% versus 90.7 ± 14.1%, p<0.05), predicted maximal voluntary ventilation (74 ± 18% versus 90.5 ± 16.2%, p<0.05) while having low-normal predicted forced vital capacity (80.5 ± 17.2% versus 90.2 ± 12.4%, p<0.05) and normal breathing reserve percentage (50.3 ± 11.3% versus 47.5 ± 17.3%, p = 0.52). Cardiopulmonary exercise testing abnormalities included significantly lower percent predicted oxygen consumption (63.2 ± 12.2% versus 87 ± 12.1%, p<0.05), maximal heart rate (171.8 ± 18.9 versus 184.6 ± 13.6, p<0.05), and percent predicted maximum workload (61.7 ± 15.9% versus 88.3 ± 21.5%, p<0.05).ConclusionsTetralogy of Fallot patients repaired with a transannular patch can have abnormal pulmonary function testing with poor exercise capacity in addition to chronotropic incompetence and impaired muscular power.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Reference27 articles.

1. Direct Vision Intracardiac Surgical Correction of the Tetralogv of Fallot, Pentalogy of Fallot, and Pulmonary Atresia Defects

2. Pulmonary and ventricular function in children with repaired tetralogy of Fallot;Demirpence;Turk Kardiyol Derm Ars,2015

3. Lung function and pulmonary regurgitation limit exercise capacity in postoperative tetralogy of fallot

4. Predictors of mid-term event-free survival in adults with corrected tetralogy of Fallot

5. Respiratory function tests: normal values at median altitudes and the prediction of normal results;Goldman;Am Rev Tuberc,1959

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3