Echocardiographic versus angiographic measurement of the aortic valve annulus in children undergoing balloon aortic valvuloplasty: method affects outcomes

Author:

Nicholson George T.ORCID,Goldstein Bryan H.,Gao Kevin,Sachdeva Ritu,Lang Sean M.,Gillespie Scott,Kim Sung-in H.,Petit Christopher J.

Abstract

AbstractObjective:Operators are mindful of the balloon-to-aortic annulus ratio when performing balloon aortic valvuloplasty. The method of measurement of the aortic valve annulus has not been standardised.Methods and results:Patients who underwent aortic valvuloplasty at two paediatric centres between 2007 and 2014 were included. The valve annulus measured by echocardiography and angiography was used to calculate the balloon-to-aortic annulus ratio and measurements were compared. The primary endpoint was an increase in aortic insufficiency by ≥2 degrees. Ninety-eight patients with a median age at valvuloplasty of 2.1 months (Interquartile range (IQR): 0.2–105.5) were included. The angiographic-based annulus was 8.2 mm (IQR: 6.8–16.0), which was greater than echocardiogram-based annulus of 7.5 mm (IQR: 6.1–14.8) (p < 0.001). This corresponded to a significantly lower angiographic balloon-to-aortic annulus ratio of 0.9 (IQR: 0.9–1.0), compared to an echocardiographic ratio of 1.1 (IQR: 1.0–1.1) (p < 0.001). The degree of discrepancy in measured diameter increased with smaller valve diameters (p = 0.041) and in neonates (p = 0.044). There was significant disagreement between angiographic and echocardiographic balloon-to-aortic annulus ratio measures regarding “High” ratio of >1.2, with angiographic ratio flagging only 2/12 (16.7%) of patients flagged by echocardiographic ratio as “High” (p = 0.012). Patients who had an increase in the degree of aortic insufficiency post valvuloplasty, only 3 (5.5%) had angiographic ratio > 1.1, while 21 (38%) had echocardiographic ratio >1.1 (p < 0.001). Patients with resultant ≥ moderate insufficiency more often had an echocardiographic ratio of >1.1 than angiographic ratio of >1.1 There was no association between increase in balloon-to-aortic annulus ratio and gradient reduction.Conclusions:Angiographic measurement is associated with a greater measured aortic valve annulus and the development of aortic insufficiency. Operators should use caution when relying solely on angiographic measurement when performing balloon aortic valvuloplasty.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Reference33 articles.

1. Evaluation of angiography as the sole imaging study for the proximal aortic neck prior to EVAR;Badger;Ulster Med J,2009

2. Long-term follow-up results of balloon valvuloplasty for congenital aortic stenosis: predictors of late outcome;Demkow;J Invasive Cardiol,1999

3. Intermediate-term effectiveness of balloon valvuloplasty for congenital aortic stenosis. A prospective follow-up study.

4. Aortic valve morphology is associated with outcomes following balloon valvuloplasty for congenital aortic stenosis

5. Twenty-Five Year Experience With Balloon Aortic Valvuloplasty for Congenital Aortic Stenosis

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Outcomes of aortic balloon valvuloplasty in newborns: A single-centre experience;International Journal of the Cardiovascular Academy;2022