The association of bicuspid aortic valve on long-term outcome following one-stage repair of aortic arch obstruction associated with ventricular septal defect

Author:

Rahatianpur MehrdadORCID,Bakhtiary Farhad,Vázquez-Jiménez Jaime,Dähnert Ingo,Kostelka Martin

Abstract

AbstractObjective:The aim of this study was to evaluate the association of bicuspid aortic valve on contemporary outcomes, including reoperation rates, after one-stage correction for interrupted aortic arch with ventricular septal defect or for aortic coarctation with hypoplastic aortic arch and ventricular septal defect.Methods:Seventy-four consecutive patients (35 boys, 47% and 39 girls, 53%) with interrupted aortic arch (n = 41, 55%) or aortic coarctation with hypoplastic aortic arch (n = 33, 45%) with ventricular septal defect underwent early one-stage correction. Twenty (27%) patients had bicuspid aortic valve, and the remaining 54 (73%) had a tricuspid aortic valve. The median aortic valve annulus diameter was 6.0 mm (IQR: 2.0). Patients’ median age was 7 ± 29 days (range, 2–150); median weight was 3.3 ± 0.7 kg (range, 1.5–6.0), with 21 (28%) patients <3.0 kg. Selective brain perfusion through the innominate artery and selective coronary perfusion through the aortic root during aortic arch reconstruction were used in all patients. Statistical analysis was performed using SPSS version 20.0 software (SPSS Inc., Chicago, IL, USA).Results:The early mortality was 1.3%. One premature neonate died in the hospital with extracorporeal membrane oxygenation after aortic coarctation plus ventricular septal defect repair. There was no further mortality. Median follow-up was 5.7 years (IQR: 10.48). Reinterventions occurred in 36 (49%) patients: balloon angioplasty in 18 (24%) patients, reoperations in 4 (5%) patients, and both in 14 (19%) patients. A total of 86 follow-up procedures were required in these 36 (49%) patients: aortic valve valvulopasty (n = 6, 8%), stent implantation (n = 8, 11%), balloon dilatation (n = 39, 53%), and reoperation (n = 33, 45%). The median time to reinterventions was 9.094 years (SE 0.890). A potential risk factor for reintervention after interrupted aortic arch and aortic coarctation with ventricular septal defect repair was bicuspid aortic valve (p = 0.019, Chi2 (1) = 5.457). In addition, a multivariate Cox analysis with backward selection and significance level <0.015 was applied to all variables that showed significant effects in univariable analyzes. This regression confirmed that bicuspid aortic valve (HR = 0.381, p = .016), and interrupted aortic arch (HR = 0.412, p = 0.043) were predictors of late reintervention. All patients had no obvious neurologic impairment in routine examinations at last follow-up.Conclusion:Bicuspid aortic valve was a significant risk factor for valve-related reintervention after one-stage repair for aortic arch obstruction with ventricular septal defect due to later development of stenosis associated with higher late morbidity and mortality. Particularly neonates with bicuspid aortic valve will possibly require reintervention in the future. Regular lifelong cardiac follow-up is recommended.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3