Extra-cardiac and complex Fontan baffle fenestration using radio frequency current via surgical electrocautery

Author:

Khan AsraORCID,Qureshi Athar M.ORCID,Bansal Manish,Stapleton Gary,Webb Melissa K.,Lam Wilson,Eilers LindsayORCID,Singh Harinder R.,Gowda Srinath T.

Abstract

AbstractBackground:Fontan baffle punctures and creation of Fontan fenestration for cardiac catheterisation procedures remain challenging especially due to the heavy calcification of prosthetic material and complex anatomy.Objectives:We sought to evaluate our experience using radiofrequency current via surgical electrocautery needle for Fontan baffle puncture to facilitate diagnostic, electrophysiology, and interventional procedures.Methods:A retrospective chart review of all Fontan patients (pts) who underwent Fontan baffle puncture using radiofrequency energy via surgical electrocautery from three centres were performed from January 2011 to July 2021.Results:A total of 19 pts underwent 22 successful Fontan baffle puncture. The median age and weight were 17 (3–36 years) and 55 (14–88) kg, respectively. The procedural indications for Fontan fenestration creation included: diagnostic study (n = 1), atrial septostomy and stenting (n = 1), electrophysiology study and ablation procedures (n = 8), Fontan baffle stenting for Fontan failure including protein-losing enteropathy (n = 7), and occlusion of veno-venous collaterals (n = 2) for cyanosis. The type of Fontan baffles included: extra-cardiac conduits (n = 12), lateral tunnel (n = 5), classic atrio-pulmonary connection (n = 1), and intra-cardiac baffle (n = 1). A Fontan baffle puncture was initially attempted using traditional method in 6 pts and Baylis radiofrequency trans-septal system in 2 pts unsuccessfully. In all pts, Fontan baffle puncture using radiofrequency energy via electrocautery needle was successful. The radiofrequency energy utilised was (10–50 W) and required 1–5 attempts for 2–5 seconds. There were no vascular or neurological complications.Conclusions:Radiofrequency current delivery using surgical electrocautery facilitates Fontan baffle puncture in patients with complex and calcified Fontan baffles for diagnostic, interventional, and electrophysiology procedures.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3