Author:
HOVER F. S.,TVEDT H.,TRIANTAFYLLOU M. S.
Abstract
Thin wires are attached on the outer surface and parallel to the axis of a smooth
circular cylinder in a steady cross-stream, modelling the effect of protrusions and
attachments. The impact of the wires on wake properties, and vortex-induced loads
and vibration are studied at Reynolds numbers up to 4.6
× 104, with 3.0 × 104 as
a focus point. For a stationary cylinder, wires cause significant reductions in drag
and lift coefficients, as well as an increase in the Strouhal number to a value around
0.25–0.27. For a cylinder forced to oscillate harmonically, the main observed wire
effects are: (a) an earlier onset of frequency lock-in, when compared with the smooth
cylinder case; (b) at moderate amplitude/cylinder diameter (A/D) ratios (0.2 and 0.5),
changes in the phase of wake velocity and of lift with respect to motion are translated
to higher forcing frequencies, and (c) at A/D = 1.0, no excitation region exists; the
lift force is always dissipative.The flow-induced response of a flexibly mounted cylinder with attached wires is
significantly altered as well, even far away from lock-in. Parameterizing the response
using nominal reduced velocity Vrn = U/fnD, we found that frequency lock-in occurs
and lift phase angles change through 180° at Vrn
[thkap ] 4.9; anemometry in the wake
confirms that a mode transition accompanies this premature lock-in. A plateau
of constant response is established in the range Vrn = 5.1–6.0, reducing the peak
amplitude moderately, and then vibrations are drastically reduced or eliminated
above Vrn = 6.0. The vortex-induced vibration response of the cylinder with wires is
extremely sensitive to angular bias near the critical value of Vrn = 6.0, and moderately
so in the regime of suppressed vibration.