Abstract
AbstractBackground:Contamination of ventriculoperitoneal shunts (VPS) by cutaneous flora, particularly coagulase-negative staphylococci, is a common cause of shunt infection and failure, leading to prolonged hospital stay, higher costs of care, and poor outcomes. Glove contamination may occur during VPS insertion, increasing risk of such infections.Methods:We performed a systematic search of the PubMed database for studies published January 1, 1970, through August 31, 2021 that documented VPS infection rates before and after implementing a practice of double gloving with change or removal of the outer glove immediately prior to shunt insertion.Results:Among 272 reports screened, 4 were eligible for review based on our inclusion criteria. The incidence of VPS infection was reduced in all 4 quasi-experimental studies with an aggregate incidence of VPS infection of 11.8% before the change in intraoperative protocol and 4.9% after protocol change. One study documented reduced hospital stay with this change in protocol.Conclusion:The risk of VPS infection is reduced by removal or replacement of the outer surgical gloves immediately prior to intraoperative insertion of a VPS as part of an infection control bundle.
Publisher
Cambridge University Press (CUP)
Subject
Infectious Diseases,Microbiology (medical),Epidemiology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献