Head mirror versus headlight: illumination, visual identification and visual acuity for otolaryngological examination

Author:

Lin C-H,Hsu H-T,Chen P-Y,Huon L K,Lin Y-Z,Hung S-H

Abstract

AbstractObjective:To investigate and compare the performance of head mirrors and headlights during otolaryngological examination.Methods:The illuminance and illumination field of each device were measured and compared. Visual identification and visual acuity were also measured, in 13 medical students and 10 otolaryngology specialists.Results:The illuminance (mean ± standard deviation) of the LumiView, Kimscope 1 W and Kimscope 3 W headlights and a standard head mirror were 352.3 ± 9, 92.3 ± 4.5, 438 ± 15.7 and 68.3 ± 1.2 lux, respectively. The illumination field of the head mirror (mean ± standard deviation) was 348 ± 29.8 grids, significantly greater than that of the Kimscope 3 W headlight (183 ± 9.2 grids) (p = 0.0017). The student group showed no statistically significant difference between visual identification with the best headlight and the head mirror (score means ± standard deviations: 56.2 ± 9 and 53.3 ± 14.1, respectively; p = 0.3). The expert group scored significantly higher for visual identification with head mirrors versus headlights (59.7 ± 3.3 vs 55.2 ± 5.8, respectively; p = 0.0035), but showed no difference for visual acuity.Conclusion:Despite the advantages of headlight illumination, head mirrors provided better, shadow-free illumination. Despite no differences amongst students, head mirrors performed better than headlights in experienced hands.

Publisher

Cambridge University Press (CUP)

Subject

Otorhinolaryngology,General Medicine

Reference8 articles.

1. ENT Today: An iconic tool: is there still a place for the head mirror? In: http://www.enttoday.org/details/article/836587/An_Iconic_Tool_Is_there_still_a_place_for_the_head_mirror.html [19 March 2012]

2. The instrument that determined my practice

3. Time structure of a goal-directed bimanual skill and its dependence on task constraints

4. Six great men in hungarian otorhinolaryngology

5. Foveal contour interactions and crowding effects at the resolution limit of the visual system

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Illumination in Spinal Surgery Depending on Different Approaches and Light Sources;World Neurosurgery;2017-09

2. Focus on the larynx;The Journal of Laryngology & Otology;2013-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3