Author:
Brown E C M,Caimino C,Benton C L,Baguley D M
Abstract
AbstractObjectivePlatinum-based chemotherapy drugs are associated with substantial ototoxicity. The hearing of children treated with these drugs should be closely monitored.MethodA questionnaire was sent out to the 19 audiology departments associated with national paediatric cancer specialist centres in the UK looking at current practice in ototoxicity monitoring.ResultsResponses were received from 17 of 19 centres (89 per cent). All offered some form of audiometric monitoring service. Extended high-frequency testing (9–20 kHz) was only utilised by 7 services (29 per cent). A majority of respondents were reluctant to consider self-test devices in paediatric ototoxicity monitoring (n = 9; 53 per cent). Provision of long-term audiological follow up is sporadic with only 4 (23 per cent) respondents keeping all children with normal hearing under review once treatment is completed.ConclusionWhile some good practice in paediatric ototoxicity was identified, opportunities exist to improve clinical practice and protocols, promote multidisciplinary team working and to utilise technologies such as extended high frequency and self-test audiometry.
Publisher
Cambridge University Press (CUP)
Subject
Otorhinolaryngology,General Medicine
Cited by