A potential danger of flexible endoscopy sheaths: a detached tip and how to retrieve it

Author:

Awad Z,Pothier D D

Abstract

AbstractObjective:To report an unrecognised complication of fibre-optic nasendoscopy, and its management.Case report:A protective, transparent nasendoscopy sheath is often used to reduce nasendoscope ‘downtime’ and to prevent cross infection, with minimal effect on the obtained image quality. We report the case of a subcutaneous tracheostomy procedure during which, without undue strain, the tip of the sheath became detached and acted as a foreign body within the trachea. A urological stone retrieval basket was used to retrieve the sheath, after failure of conventional methods.Discussion:Clinicians should be aware that any instrument introduced into the airway has the potential to fail and in the process produce a foreign body which may cause serious complications. The urological stone retrieval basket may be a useful addition to the current set of instruments used to deal with difficult airway foreign bodies.

Publisher

Cambridge University Press (CUP)

Subject

Otorhinolaryngology,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3