Epidural application of ionomeric cement implants. Experimental and clinical results

Author:

Geyer G.,Baier G.,Helms J.

Abstract

AbstractDuring setting and hardening, the hybrid bone substitute ionomeric cement (lonocem®) achieves a stable and durable bond with the apatite of the adjacent bone without interpository soft tissue. Fluid contact during setting results in the release of aluminium ions which may reach critical levels as high as 3000 μg/l. On epidural application it is, therefore, essential to prevent cement constituents from gaining access to the intradural space. After the cement has hardened, the presence of aluminium is demonstrable in the adjacent bone to a maximum depth of 20 μm (EDX microanalysis). In rabbits, epiduralplacement of freshly mixed cement causes slight thickening of the dura. There is reason to believe that human dura, with a thickness 10 times greater, is impermeableto components of the cement. After epidural application of the freshly mixed cement in the frontobasal and laterobasal regions and at the skull cap and petrous apex, 76 patients in all have been followed for up to 6.5 years. During this period no complications have arisen and functional (and cosmetic) results are promising. The availability of preformed implants (lonoroc®, lonocast®) permitted the peridural placement of minimal quantities of freshly mixed cement. These implants were fixed to localized sites on the adjacent calvarial bone by use of lonocem®. Notwithstanding the stringent manufacturer guidelines, there have been reports in the literature that during the vulnerable stage of setting neurotoxic aluminium ions were released into the dural space with a fatal outcome intwo cases. In view of potential intradural complications, such as may occur in case of dural leaks, it was considered that further application of the material adjacent to the dura was no longer warranted. The production of lonocem® was discontinued in May 1995.

Publisher

Cambridge University Press (CUP)

Subject

Otorhinolaryngology,General Medicine

Reference41 articles.

1. Städtgen A. (1994) Tierexperimentelle Untersuchungen zum Verhalten von Glasionmerzement in der Kopf-Hals-Region–eine histologische Studie an Pavianen (Papio ursinus). Inauguraldissertation, Würzburg.

2. Encephalopathy with seizures after use of aluminium-containing bone cement

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Influence of the thermal treatment on the characteristics of porous geopolymers as potential biomaterials;Materials Science and Engineering: C;2020-11

2. Innovative applications of inorganic polymers (geopolymers);Handbook of Alkali-Activated Cements, Mortars and Concretes;2015

3. Calcium-containing inorganic polymers as potential bioactive materials;Journal of Materials Science;2010-02

4. Comparison of failure mechanisms for cements used in skeletal luting applications;Journal of Materials Science: Materials in Medicine;2009-03-13

5. Acute Aluminum Intoxication;Group 13 Chemistry II;2002

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3