Evaluation of dose calculation accuracy of a commercial radiotherapy treatment planning system for adjacent radiation fields

Author:

Rasouli Ali,Naraqi Arani Mahmud,Aliasgharzadeh Akbar,Farhood BagherORCID

Abstract

AbstractBackground:Adjacent radiation fields are applied in some radiotherapeutic cases. When using these radiation fields, considerable dose errors across the junction of radiation fields are possible. Therefore, it is necessary to evaluate the accuracy of the dose calculated by treatment planning system (TPS) when using the adjacent radiation fields. The present study aimed to quantify the dose calculation accuracy of ISOgray TPS for the photon-photon adjacent fields.Materials and methods:To assess the accuracy of dose calculations, the dose profiles were first measured by a Semiflex ionization chamber at 1, 1·5, 5 and 10 cm depths for different field sizes (6 × 6, 10 × 10 and 20 × 20 cm2), source to surface distances (SSDs) (90, 100 and 110 cm) and beam angles (0º, 15º, 30º and 45º). In the second step, the data at corresponding depths were extracted from the ISOgray TPS. Finally, the dosimetric performance of TPS was evaluated using a gamma index analysis.Results:The overall dose calculation accuracy of ISOgray TPS was within the acceptable range for the build-up region (with acceptance criteria of dose difference (DD) = 15% and distance to agreement (DTA) = 3 mm) and the depths after the build-up region (with acceptance criteria of DD = 5% and DTA = 3 mm). Moreover, the overall accuracy of dose calculations was not affected by the field size and the SSD. It was also shown that the accuracy of dose calculations was similar for the adjacent radiation fields with beam angles of 0º, 15 º and 30 º, while a considerable decrease in the pass rate values is obtained for the adjacent radiation field with 45 º beam angle. A more detailed analysis of the findings revealed that the accuracy of dose calculations in the match line regions of the adjacent radiation fields for 1 cm beam profiles was within the acceptable range; however, it declined for other depths.Conclusions:The findings showed that the overall dose calculation accuracy of ISOgray TPS was acceptable for evaluated adjacent radiation fields. However, the accuracy of dose calculations in the match line regions of the adjacent radiation fields for the depth after build-up was not within the acceptable range.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3