Evaluation of three dimensional conformal radiation therapy of oesophageal cancer: a dosimetric study

Author:

Zulkafal Hafiz Muhibb ullah,Iqbal Muhammad Mazhar,Akhtar Muhammad Waqas,Iqbal Khalid,Khan Muhammad Afzal

Abstract

AbstractAimsThe main objective of this research work is to compare the dosimertic effect on lower and upper oesophagus cancer treatment using 3D conformal radiotherapy as well as to evaluate the doses administered to the organs at risk.Materials and methodsIn this study, a cohort of 30 oesophageal cancer patients between the ages of 45 and 67 years registered during March 2017 to February 2018 was considered. These patients were treated through 3D conformal radiotherapy using four-field technique. Beam energy of 15 MV from Varian DHX linear accelerator was used. The given 30 patients were divided into two groups. The 1st group of 15 patients with upper oesophagus cancer was prescribed 5000 cGy doses, and the 2nd group of remaining 15 patients with lower oesophagus cancer was prescribed 4500 cGy. Computed tomography scans of every patient were obtained and then transmitted to Eclipse TPS for generating treatment plans. All radiotherapy plans were evaluated through various dosimetric indices. Statistical analysis software SPSS was utilised to get the values of means standard error and standard deviation of these indices for the treatment plan evaluation.ResultsUniformity index (UI) calculated for first group of patients showed difference of 7·4% from ideal value. A difference of 7% between ideal and calculated UI value was observed in 2nd group of patients. The values of other dosimetric indices like coverage, homogeneity, moderate dose homogeneity index (mDHI) and radical dose homogeneity index (rDHI) were found in limits specified by the Radiation Therapy and Oncology Group. The maximum difference of 6% was observed between the coverage mean values of 1stand 2ndgroup treatment plans.ConclusionFor oesophageal cancer, 3D conformal radiotherapy using four-field treatment plans shows homogeneous distribution of dose around the target and limits the dose to organ at risk.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3