Virtual simulation and treatment verification–merits and demerits: experience at Sindh Institute of Urology and Transplantation (SIUT), Pakistan

Author:

Tunio Mutahir,Rafi Mansoor,Maqbool Aamir,Haque Asdarul

Abstract

Background: The rapid changes in practice of radiotherapy have taken place over the past 5 years in Pakistan. With advent of computed tomography simulator, and multileaf collimators–assisted linear accelerators and electronic portal imaging system, few centres in Pakistan have switched from conventional radiotherapy to modern computer-based technology. Our hospital is first centre in Pakistan which is using virtual simulation since March 2006. We present our experience with list of merits and demerits.Design: Retrospective study.Patient collection: Medical records of all patients who received radiotherapy in our centre were reviewed. Parameters included were type of malignancy, type radiotherapy (curative/palliative), simulation and planning process time and the displacement of the beam-axis from the planning isocentre in clinical situations during three-dimensional conformal radiotherapy using electronic portal imaging device (EPID). Data were collected on written proforma. Percentages, frequencies, measures of central tendency and dispersion were calculated using SPSS version 17.0.Results: A total of 289 patients were treated from March 2006 to November 2008. Transitional cell carcinoma of urinary bladder was most common malignancy seen (42.4%) followed by prostate (28.62%) and renal cell carcinoma (14.14%). Of these 34.26% patients were treated on curative basis. The virtual simulation process could be completed in an average time of 5 min (SD 3.5). Under many cases, the treatment portals could be designed and the patient marked in one session. The displacements were recorded for 43 portals for early prostate cancer using an EPID system. The mean displacement was found 2.44 ± 0.8 mm in x (transverse), y (craniocaudal), and z (anteroposterior) directions during treatment. Standard deviation (SD) was 0.87 (90% CI 2.21–2.66). Average number of portals taken was 10 (6–27) per treatment session.Conclusion: Computer-based simulation and treatment over conventional methods is appropriate for curative patients, achieving more accurate tumour localisation, sparing normal organs at risk, reduced field sizes and a film free environment; however efforts are required to achieve maximum immobilisation during treatment.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3