In vivo dosimetry; essential or unnecessary?

Author:

Leman Jenna L

Abstract

AbstractIntroduction: The radiotherapy profession has learned from errors made during treatment planning and delivery. Quality assurance in radiotherapy (QART) procedures are implemented to reduce the risk of an error occuring. The chief medical officer, along with others, has recommended that the QART of all departments includes in vivo dosimetry (IVD) to ensure that the delivered dose equals the planned dose.Why we need IVD: A lot of effort goes into field verification and it is just as vital that dosimetry is verified. Overdose to normal tissue can cause devastating side effects, even death, whilst tumour underdose may compromise control. Without IVD, there is no way of knowing that a patient is receiving an overdose until it is too late. Underdoses are unlikely to manifest without IVD. IVD allows radiotherapists and physicists to correct for dose errors in a timely manner.Why IVD is unnecessary: Radiotherapy accidents are rare. Implementing IVD is expensive, time consuming and takes resources away from developing techniques which will improve patient outcomes. Current IVD methods are not suitable for modern techniques such as intensity modulated radiotherapy (IMRT).Discussion: IVD appears to be a useful QART tool, particularly as dose escalation techniques develop allowing a higher dose to be delivered to the tumour. Departments may be unwilling to spend time and money on an IVD system that is costly and time consuming if it cannot perform IVD on modern techniques. Electronic portal imaging devices (EPIDs) can be utilised to perform IVD on complex techniques, such as IMRT and arc therapy, which current IVD methods cannot, however there is currently no EPID IVD system available commercially.Conclusion: Ideally, all departments would conduct IVD on all new patients. IVD has proven to be an important QART tool, however, until technology is developed to allow EPID to include IVD, the procedure is not likely to be implemented countrywide.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Reference30 articles.

1. Lanson JH , Essers M , Uiterwaal GJ et al. In vivo dosimetry: An essential part of a quality assurance programme of conformal radiotherapy. Radiother Oncol submitted.

2. The cost effectiveness ofin vivodosimetry is not proven

3. Can we afford not to implementin vivodosimetry?

4. In vivo dosimetry by an aSi-based EPID

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3