Dose distribution in 3-dimensional conformal radiotherapy for prostate cancer: comparison of femur doses for four treatment techniques

Author:

Karaçetin Didem,Çakır Aydın,Ağaoğlu Fulya,Çamlıca Hakan,Ergen Arzu,Dizdar Yavuz,Darendeliler Emin

Abstract

AbstractPurpose: Conformal radiotherapy of the prostate is an increasingly common technique in the treatment of prostate cancer. When using 3D conformal radiotherapy (CFRT) methods, it is desirable to protect the vital structures such as bladder, rectum, and femur. In this study, our aim was to compare the femur head doses resulting from co-planar beam arrangements in four-field (4F), five-field (5F), six-field (6F) and seven-field (7F) treatment plans, in a dose-escalated CFRT schedule.Materials and Methods: From January 2005 to December 2006, at Istanbul University Medical Faculty of Radiation Oncology Clinic, a total of 22 patients with carcinoma of the prostate had been scanned using computed tomography (CT) (0.50 mm) in the supine position. During the CT scanning which used the Sim Pro (CMD–USA) programme, planned target volume (PTV), clinical target volume (CTV), and dose volumes received by the bladder, rectum and femur heads were recorded and dose–volume histogram (DVH) were created. The dose volume relating to prostate and seminal vesicles was termed CTV 1, and the dose volume relating to prostate alone was termed CTV 2. During the formation of PTV, into CTV 1, from the anterior-superior-inferior 8 mm, and from posterior 5 mm tolerance were taken into account. After volume determination is calculated using XiO (CMS-USA) 3D treatment planning computer, each patient 4F (45° – 25%, 135° – 25%, 225° – 25%, 315° – 25%), 5F (0° – 20%, 45° – 20%, 90° – 20%, 270° – 20%, 315° – 20%), 6F (45° – 20%, 90° – 10%, 135° 20%, 315° – 20%, 270° – 10%, 225° – 20%) and 7F (0° – 4%, 45° – 12.9%, 90° – 22.2%, 135° – 12.9%, 315° – 12.9%, 270° – 22.2%, 225° – 12.9%) was entered; 70 – 76 Gy was calculated to be given to prostate lodge. With the use of Siemes Oncor, 18 MV photons CFRT was applied. In DVH analysis, following were observed: V50, minimum and maximum doses for head of left femur and right femur total doses.Results: Our statistical evaluation was made using SPSS software, and we found femur doses following; 4F V50 1030 cGy (minimum 58, maximum 1390), 5F V50 2425 cGy (minimum 540, maximum 3631), 6F V50 1769 cGy (minimum 1234, maximum 3912) and 7F V50 3230 cGy (minimum 2150, maximum 4137). In comparing different techniques, the greatest rectal sparing was achieved by the 5F plan. (Rectal: 5F V%25 = 59.90 ± 6.8 Gy, 4F V%25 = 62.30 ± 10.3 Gy, 6F V%25 = 69.36 ± 5.7 Gy, 7F V%25 = 61.32 ± 7.3 Gy). The greatest femoral head sparing was achieved by the 4F techniques. When paired samples t-test was made, we found considerable lower femur doses for 4F techniques (p = 0.05).Conclusion: We concluded that, during radiotherapy to treat carcinoma of the prostate, the dose received by the rectum is the most important factor to consider, given the potential for late toxicity in this organ. However, while using lateral fields (90–270°) so as to protect the rectum, the doses received by the femur heads were observed to be higher. Especially in older patients, the critical doses of 52 Gy for TD5/5 and 65 Gy for TD 50/5 were observed to be not reached late toxicity for 4F, 5F, 6F and 7F.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3