Dosimetric comparison of constant dose rate volumetric modulated arc therapy (CDR-VMAT) and intensity-modulated radiation therapy (IMRT) for gallbladder cancer

Author:

Gedam Varsha R.ORCID,Pradhan Anirudh

Abstract

Abstract Aim: To study the feasibility of constant dose rate volumetric modulated arc therapy (CDR-VMAT) in radiotherapy for gallbladder cancer by comparing dosimetric parameter suggested by International Commission on Radiation Units and Measurements-83 (ICRU-83) with step and shoot intensity-modulated radiation therapy (SS IMRT). Methods: For this study, we selected 21 post-operative gallbladder cancer patients, which were treated with the IMRT technique from 2016 to 2019. For each patient, we generated SS IMRT plan and CDR-VMAT plan and were dosimetrically compared by parameters suggested by ICRU-83 for PTV. Homogeneity Index (HI) and Conformity Index (CI) were also calculated. For evaluation of Organ at Risk (OAR), we compared the mean doses, volume doses to the right kidney, left kidney, both kidneys combined, liver and max dose to the spinal cord. Monitor units (MUs) and treatment delivery time were also compared. Results: On comparing, we found that CDR-VMAT plans were highly conformed as CI and PCI (CI define by Paddick) were found more (0·98 ± 0·01 vs. 0·97 ± 0·03 and 0·86 ± 0·05 vs. 0·85 ± 0·05) than IMRT plans but not statistically significant. Better dose HI was found for IMRT plans with statistical significant difference (p < 0·001). The tumour coverage was found similar 98·24% and 97·83% for SS IMRT and CDR-VMAT, respectively. For D2%, the maximum dose to PTV was significantly lower in IMRT (p = 0·001). D50% and mean dose to PTV were also comparable to IMRT with no statistically significant difference. The OAR parameters were comparable in both the techniques. The mean doses and volume doses V10, V20 and V30 to the right kidney, left kidney and liver were also comparable with no significant difference (p > 0·05) was noted among them. However, the maximum dose to the spinal cord was significantly less in CDR-VMAT (21·1 Gy vs. 25·1Gy) than SS IMRT with p = 0·006. More MUs were associated with the CDR-VMAT technique, but shorter treatment delivery time than the IMRT technique. Conclusions: On dosimetric comparison of two treatment techniques, we conclude that CDR-VMAT can be a valid option in radiotherapy as it achieved highly conformed dose distribution, comparable tumour coverage and OAR sparing as IMRT technique for gallbladder cancer.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3