Postoperative endometrial cancer treatments with electronic brachytherapy source

Author:

Lozares-Cordero Sergio,Font-Gómez Jose Antonio,Gandía-Martínez Almudena,Méndez-Villamón Agustina,Villa-Gazulla David,Miranda-Burgos Anabela,Alba-Escorihuela Verónica,Jiménez-Puertas Sara

Abstract

AbstractPurposeThis study is a dosimetric and acute toxicity comparison of endometrial cancer patients treated with either Axxent (Xoft, Inc., San José, CA, USA) electronic and interstitial brachytherapy versus interstitial high dose rate brachytherapy (HDRBT).Materials and MethodsBetween 2015 and 2017, 94 patients with postoperative endometrial cancer were treated in our centre with the Axxent electronic brachytherapy (eBT) system. The V150 and V200 are evaluated prospectively for each plan. The mean age of patients was 65.9 years (age range 33–84 years), with different tumour staging. Of the 94 patients, 37 received exclusive adjuvant brachytherapy (25 Gy in five sessions); the remaining patients received external beam radiotherapy (EBRT) with a regimen of 23 sessions of 2 Gy each to the entire pelvis, followed by eBT (15 Gy in three sessions). Additionally, the absorbed doses received by the organs at risk (OAR), urinary bladder, rectum and sigmoid colon were compared with HDRBT plans, evaluating D2cc, V50% and V35%. Median follow-up was done for each of the 94 patients to assess the toxicity of the treatment: vaginal mucosa toxicity, rectal and urinary toxicity; and results are presented for acute toxicity, toxicity at 1 month after the end of treatment and follow-up after 12 months for a portion of patients according to the Radiation Therapy Oncology Group (RTOG) toxicity criteria.ResultsThe doses in OAR for eBT plans were lower than that for HDRBT plans, both Ir-192 and Co-60 plans, whose doses were similar. The dose in bladder with eBT was 63.8% of the prescribed dose for D2cc versus 70.1% for HDRBT Ir-192, for V50% was 7.2% versus 12.7% and for V35% was 15.2% versus 28.2%. In rectum the D2cc was 61.2% versus 68.4%, for V50% was 7.9% versus 14.3% and for V35% was 16.7% versus 32%. Results demonstrated lower doses to OAR in all eBT plans. Acute toxicity in eBT was very low in cases of mucositis, with only one case of toxicity greater than grade 1, rectal toxicity and urinary toxicity; results at 1 month are equally good, toxicity symptoms disappeared and no relapses have occurred to date.ConclusionsThe results of treatment with the Axxent eBT unit for 94 patients are very good, as no recurrence has been observed and the toxicity of the treatment is very low. The increase in V150 and V200 has not produced an increase in vaginal mucosa toxicity, and the doses in the OAR are lower than in the plans implemented for HDRBT with Ir-192 or Co-60. eBT is a good alternative to treat endometrial cancer in centres without conventional HDR availability. To date, there are limited published studies reporting on outcomes from patients treated with eBT.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3