Prospective observational study to estimate set-up errors and optimise PTV margins in patients undergoing IMRT for head and neck cancers from a Government cancer centre of Eastern India

Author:

Biswas Priyanka,Lahiri DebarshiORCID,Roy Sanjoy,Maji Tapas,Bhadra Kallol,Ray Dilip Kumar,Das Subhadip,De Palas,Mohanta Bijan Kumar

Abstract

AbstractBackground:The head and neck cancers as a whole are the most common cancers among males in India. Technological advancements have led to an improvement in radiation therapy (RT) techniques with subsequent reduction in normal tissue complications. To correct patient set-up errors, an off-line correction method like no action level (NAL) protocol may be used as a preferred protocol particularly for a busy department. The objectives of the study were to measure the translational set-up errors using kV cone-beam computed tomography (CBCT) in patients undergoing intensity modulated radiotherapy (IMRT) in head and neck cancers and also to optimise clinical target volume (CTV) to planning target volume (PTV) margin using NAL protocol.Material and methods:On the first 5 days of RT, patient’s position was verified by kV-CBCT and then weekly during the course of treatment. The comparison between the reference and kV-CBCT images was performed, and the shifts measured and recorded. The mean error from the initial five consecutive fractions was corrected on the sixth daily fraction. Displacements in all the directions were measured. The population systematic and random errors were determined and used to estimate PTV margins according to the van Herk formula.Results:A total of 322 images were analysed. Before correction, 15, 12 and 9% patients had systematic error ≥3 mm on X, Y and Z axes, but after correction this was reduced to 9, 0 and 0%. The total percentage of patients whose set-up margin was ≥5 mm before correction was 5, 6·25, 3·75%, but after correction it reduced to 1·88, 0, and 0·63%. The margins of total population were reduced to 63, 65 and 56% after correction on X, Y and Z axes, respectively.Conclusion:A simple off-line NAL protocol can correct the set-up errors without daily on-line imaging in patients undergoing IMRT and hence acting as a resource sparing alternative. Five millimetre margin to CTVs was adequate and safe to overcome the problem of set-up errors in head and neck IMRT.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3