To analyse target volume variations during SIB-IMRT of squamous cell carcinoma of uterine cervix

Author:

Shamsi Qurat-ul-AinORCID,Iqbal Khalid,Jabeen Shagufta,Buzdar Saeed Ahmad

Abstract

AbstractPurpose:To assess volume variations in target site due to changes in bladder filling and rectal content including air bubbles during simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) of patients suffering from squamous cell carcinoma of uterine cervix.Materials and methods:A total of ten patients of squamous cell carcinoma of uterine cervix were enrolled in this analysis. All patients were planned to undergo SIB-IMRT using 10 MV beam. Planning target volume of the tumour (PTVtumour) and PTVnodal were prescribed with 5,040 and 4,500 cGy doses, respectively. During planning, PTVtumour V95%, PTVnodal V95% and organs at risk (OARs) (bladder, rectum, femoral heads and small bowel) volumes were measured from initial CT planning scans taken with full bladder. CT scans were acquired once in a week over a treatment period of 5·5 weeks. Intra-treatment scans with full bladder were then fused with the planning scans to determine variations in the target volume and the OAR volume. Changes in radiation dose to the PTVtumour and the PTVnodal were also assessed by comparing intra-treatment scans with the planning (first) scans.Results:All patients showed intra-treatment bladder volume larger than the planning bladder volume. Difference between planning bladder and intra-treatment bladder volumes ranged from 4·5 to 49%. Rectal volume varied from 17 to 60 cc. A wide variation between planning and intra-treatment air volumes was found in most of the patients. When comparing initial and inter-fraction air volumes, the maximum difference was 366·67%. Due to bladder and rectal volume variations, PTVtumour V95% and PTVnodal V95% doses did not remain constant throughout the treatment. The maximum discrepancy between intra-treatment PTVtumour dose and planning PTVtumour dose was 12·15%. The maximum difference between planning and inter-fraction PTV V95% was 48·28%. PTVnodal dose observed from scan taken in last week of treatment was 12·87% less than planning PTVnodal dose analysed from planning CT scan. Maximum difference in planning and inter-fraction PTVnodal V95% was 57·78%.Conclusion:Inconsistent bladder and rectal volumes had a significant impact on target volume and dosage during an entire course of SIB-IMRT. For radiotherapy of gynaecological malignancies, data on variations in PTV should be acquired on daily basis to target radiation dose to the tumour site with accuracy.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3