Trajectory modulated arc therapy using quasi-continuous couch motion layered on top of volumetric modulated arc therapy in left breast and chest wall irradiation: a feasibility study

Author:

Sarkar Biplab,Pradhan Anirudh

Abstract

AbstractAimTo investigate the dosimetric advantage of quasi-continuous couch motion-enabled trajectory modulated arc radiotherapy therapy (TMAT) over the coplanar tangential partial arcs volumetric modulated arc radiotherapy (VMAT) for treating left breast and chest wall patients.MethodTreatment plans of 43 patients who received radiotherapy for left breast (17) or for left chest wall (26) using coplanar partial tangential arcs VMAT (reference plan) were considered for this study. For each patient, in addition to the treatment plan, a TMAT plan was also generated using quasi-continuous couch rotation. The TMAT plan consisted of original two 30° tangential arc beams and two supplementary beams having a couch rotation of ±10°, ±20° and ±30°, respectively. The difference in PTV volume coverage (PTV V95%) between TMAT plan and VMAT plan was calculated for all the cases and normalised to the plan’s prescription dose. Similarly, differences in PTV_V105% and several dose-volume parameters related to organs at risk (OAR) were also computed and tabulated.ResultTMAT shows an increment in the PTV dose coverage V95% with respect to reference plan by 4·7±2·5% when averaged overall prescription dose levels. Mean PTV dose (averaged overall prescription levels) for reference and TMAT plan was 4638·6±423·8 and 4793·5±447·2 cGy, respectively, and statistically insignificant (p=0·06). However mean PTV_V105% values for TMAT and for reference plans were 6·7±4·8 and 7·2±5·2%, respectively, and were not statistically different (p=0·85). Mean heart dose in TMAT was less than in VMAT plans, but not significantly. As regarding D1% to heart, TMAT plan was again found to be better with a mean difference of 137·1 cGy over VMAT plan. Other parameters evaluated were: mean dose and D1% to contralateral breast, and V20 Gy and V5 Gy for lung.ConclusionTMAT plans were found to be better than VMAT plans in terms of PTV coverage and D1% for heart. For evaluated dose parameters apart from PTV coverage and D1% to the heart, no significant differences were observed. Thus, TMAT plans yielded better dose distribution in terms of PTV dose coverage, hot spots and OAR doses.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3