Experimental determination of breast skin dose using volumetric modulated arc therapy and field-in-field treatment techniques

Author:

Cardona-Maya Ana María,Rojas-López José AlejandroORCID,Germanier Alejandro,Murina Patricia,Venencia Daniel

Abstract

Abstract Introduction: The use of volumetric modulated arc therapy (VMAT) on the breast has several dosimetric advantages but its impact on skin dose should be evaluated and compared to well-established treatment techniques using tangential fields. The aim of this work is to contrast the skin dose for VMAT and field-in-field (FIF) and to estimate the magnitude of the skin dose involved. Method: The skin dose was measured, without build-up, using thermoluminescent dosimeter (TLD) and optically stimulated luminescence dosimeter (OSLD) in breast radiotherapy by an in-house anthropomorphic phantom. Two different treatment techniques were used: FIF and VMAT, based on the planning strategy proposed by Nicolini et al. The dose levels were 4300 cGy, 4600 cGy and 5600 cGy in 20 fractions. In vivo dosimetry with TLD for VMAT was performed for different breast sizes in the same locations as phantom measurements. Results: The ipsilateral phantom breast skin dose using both treatment techniques was equivalent. TLD measured doses by the VMAT technique were up to 5% higher than OSLD, although they agree if we consider the geometry uncertainty of the TLD. In accordance with in vivo dosimetry, the mean dose of the ipsilateral breast skin was 62 ± 6% (51%, 75%) relative to the prescribed dose, regardless of the breast size for the volumes considered with this small population (n = 9) as shown by Mann–Whitney U-test (Z = 1·9, 95% confidence). The uncertainty expected in this region due to geometry (volume) changes is up to 9% higher for volumes from 225·9 cc to 968·8 cc. According to the treatment techniques and in vivo dosimetry, the contralateral breast skin dose was 1·0% in FIF and 2·5% in VMAT concerning the prescribed dose. Conclusion: There is no difference in skin dosimetry between VMAT and FIF techniques on the ipsilateral breast. It provides useful support for the use of VMAT as a planning technique for breast irradiation. The work describes the importance of quantifying potential differences in skin dosimetry.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3